This article takes a closer look at the IMP-C series of LS motor protection relays.

IMP-C series features

  • Display-equipped electronic motor protection relay with competitive pricing
  • Detachable display for door mounting using a connecting cable
  • RS-485 or 4–20 mA output available as separate versions; not simultaneous on the versions described here
  • Stores up to five fault events, including date and time
  • Manual, automatic and electrical reset options
  • Total running hours and operating-hour setpoint
  • Three-phase digital ammeter: displays the phase currents in sequence at two-second intervals
  • Wide current adjustment range: application from 0.125 to 100 A with the appropriate model configuration
  • Wide ground-fault sensitivity adjustment and dual detection: zero-sequence and residual-current detection are provided for flexible, economical protection configurations.

IMP-C ratings

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 2

IMP-C model designation

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 3

IMP-C current-rating variants

The IMP-C series is divided into the current ratings shown below.

  • IMP-C-10A : 10A (0.5~10A)
  • IMP-C-100A : 100A (5~100A)

These are the available configurations. The 10 A version is mainly used with CTs; the 100 A version is used for direct current sensing.

IMP-C protection functions (common EMPR terminology)

  • Overcurrent/overload: current exceeding the motor's rated value, creating a risk of overheating.
  • Locked rotor: the rotor is stationary or mechanically locked; current may reach 5–7 times rated current and overheat the motor.
  • Phase loss: one of the three supply phases is lost, potentially causing excessive current in the remaining phases.
  • Unbalance: uneven phase currents. The source uses an unbalance ratio above 30% as an example; the applicable threshold follows the model settings.
  • Phase reversal: a change in phase sequence.
  • Ground fault: an unintended current path from a live conductor to earth or a grounding conductor. Ground fault and leakage current are not interchangeable terms in every application.
  • Automatic reset: restores the relay after the configured delay following an overcurrent trip; assess the possibility of automatic restart.
  • Instantaneous protection: the source describes operation within 50 ms for fault currents at 500–1,500% of rated current or above, according to the selected setting and model.

These are the main protection terms used for EMPR products.

IMP-C operating-time characteristics

  •  Inverse-time operation  : Above the set current, the trip time varies with the magnitude of the overcurrent. 
    • Loads with inverse-time thermal characteristics, such as motors
  •  Definite-time operation  : Above the set current, the relay operates after a fixed time regardless of the magnitude of the overcurrent within the applicable characteristic. 
    • Loads such as electronic circuits, heaters and lighting where definite-time protection is appropriate

IMP-C ground-fault variants, additional functions, communications and other outputs

  • NO-: basic version with standard ground-fault protection
  • A420: 4–20 mA output version
  • M485 : RS485 Modbus

Select the product by combining the required elements shown above.

IMP-C accessories

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 4

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 5

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 6

ZCT: for ground-fault detectionCT: for higher-current detection (60 A and above in the source example)Cable: for door mounting
  • A cable is required for a door-mounted display: 1 m, 1.5 m, 2 m, 3 m or 4 m.
  • A ZCT is required for external ground-fault detection. The source identifies the N type as having an integrated ZCT, requiring no separate ZCT for that function.
  • CTs are used for higher currents or through-window sensing without disconnecting the load conductor. Two or three CTs are required according to the sensing arrangement.

IMP-C front-panel layout

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 7

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 8

IMP-C terminal arrangement

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 9

IMP-C circuit diagrams

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 10

IMP-C flush-mount panel dimensions

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 11 

IMP-C dimensions

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 12

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 13

LS EMPR electronic motor protection relay reference page

2SK Retail EMPR Page >

LS IMP-C Motor Protection Relay: Features and Wiring — original reference image 14

2SK Retail, Engineering and Blog

E.mail.  2sk@2sk.co.kr    Tel. 1833-7728    Fax. 031-479-3585

Need help selecting the right product?

Send your model number, motor nameplate and required quantity to 2SK.

Request a quotation →Email 2SK →

#IMPC #EMPR #MotorProtectionRelay #LSRelay #LSELECTRIC #2SK

English edition by 2SK. Original catalogue/reference images are retained; some labels within images are in Korean. Read the original Korean article

2SK Tech Blog

E.mail. 2sk@2sk.co.kr  Tel.1833-7728  Fax.031-479-3585


Company Name: 2SK 

Business Registration No.: 657-76-00077


Store: #16-111, Anyang International Distribution Complex, 92 LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Postal Code 14771, Republic of Korea

Office: Room 503, Building B, Geumjeong Station 3rd SK V1 Center, 91 LS-ro 116beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Republic of Korea

Factory: 1F, 27 Heongan-daero 49beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Republic of Korea


CEO: Shin Jae-woon


Mail-Order Business License: No. 2017-Anyang Dongan-0311

Retail Webpage: https://2sk.co.kr

Copyright: Copyright ⓒ 2SK SOLUTION. All rights reserved.


MON-FRI · AM 09:00 ~ PM 05:00
LUNCH · PM 12:00 - PM 01:00
SAT.SUN.HOLIDAY OFF